
Bradley Buecker
American television director and film producer
4
APPEARANCES
1
PODCASTS
012
DEC 30
JAN 6
JAN 13
JAN 20
JAN 27
FEB 3
FEB 10
FEB 17
FEB 24
MAR 3
MAR 10
MAR 17
MAR 24
MAR 31
APR 7
APR 14
APR 21
APR 28
MAY 5
MAY 12
MAY 19
MAY 26
JUN 2
JUN 9
JUN 16
JUN 23
JUN 30
JUL 7
JUL 14
JUL 21
JUL 28
AUG 4
AUG 11
AUG 18
AUG 25
SEP 1
SEP 8
SEP 15
SEP 22
SEP 29
OCT 6
OCT 13
OCT 20
OCT 27
NOV 3
NOV 10
NOV 17
NOV 24
DEC 1
DEC 8
DEC 15
DEC 22
DEC 29
JAN 5
JAN 12
JAN 19
JAN 26
FEB 2
FEB 9
FEB 16
FEB 23
MAR 2
MAR 9
MAR 16
MAR 23
MAR 30
APR 6
APR 13
APR 20
APR 27
MAY 4
MAY 11
MAY 18
MAY 25
JUN 1
JUN 8
JUN 15
JUN 22
JUN 29
JUL 6
JUL 13
JUL 20
JUL 27
AUG 3
AUG 10
AUG 17
AUG 24
AUG 31
SEP 7
SEP 14
SEP 21
SEP 28
OCT 5
OCT 12
OCT 19
OCT 26
NOV 2
NOV 9
NOV 16
NOV 23
Nov 20, 2026
Flow-Accelerated Corrosion: Don’t Wait for a Failure
8:02
8:16
8:22
8:37
8:49

Brad BueckerGUEST
But going back in time, way back to, you know, fairly early in the last century, you know, boilers started to increase in pressure and size as they became used for power generation.

Brad BueckerGUEST
You know, as electricity expanded around the country, you know, everybody wanted to have power.

Brad BueckerGUEST
Well, we've got to generate the power and fossil fire boilers, coal fire boilers and others, oil fire boilers, came online to you know, generate the steam that drove the turbines to produce the power.

Brad BueckerGUEST
So everybody was looking for advancements and higher pressures and temperatures because thermodynamically that improves the efficiency of the entire process.

Brad BueckerGUEST
Well, during that time, especially in the mid-50s, and again, I'm focusing on the feedwater network of these units, chemists and researchers and so forth had concluded that And I'll back up a little bit.
10 MINS LATER
Remote Cooling System Failures Are Rarely Sudden
2:48
3:02
3:23
3:33
3:44
3:58
6:57

Traci PurdumHOST
So my question to you is, what are the earliest, easiest-to-miss signs that one of these out-of-the-way systems is deteriorating, and why do operators so often overlook them?

Brad BueckerGUEST
Well, i-in the first, uh, place, uh, you know, with these systems being, uh, scattered around, especially at large fa-- utilities and, uh, industrial plants, uh, it, it can be easy to overlook some of the systems, especially maybe some of the small systems.

Brad BueckerGUEST
As far as early detection, um, and, and some of this comes from my own experience, and I'll mention a little bit of, bit of it here in a few minutes.

Brad BueckerGUEST
But, uh, in cooling systems, scale formation and microbiological fouling can, can cause, obviously, heat transfer degradation.

Brad BueckerGUEST
And with a good monitoring program, you know, somebody that's experienced and, and has the proper training, uh, they can detect some of these problems coming on, uh, before things really get serious.

Brad BueckerGUEST
Now with, with microbes, and, and I've dealt with those a lot, that's probably -- And it's not just my opinion, a lot of my colleagues, too, that can be the number one problem.

Traci PurdumHOST
Now, why are s- are the potential problems often exacerbated in systems with cooling towers as compared to once-through systems?
Reverse Osmosis: When It's Time to Ditch the Softener
5:58
6:16
6:21
15:30

Traci PurdumHOST
Now, what about the existing equipment and what needs to be done, and what does a well-designed RO pretreatment setup need to include here? to keep the membranes protected over the long term? And where do you see plants cutting some corners on things like this?

Brad BueckerGUEST
Cutting my teeth in the industry for so many years and learning so many things.

Brad BueckerGUEST
There are two philosophies that they're kind of counter to each other that I've seen over the years.
9 MINS LATER

Traci PurdumHOST
How can operators tell when an RO system is starting to drift out of spec before it becomes a real problem? And what should they be keeping an eye on day to day?
Condensate Recovery: Know What’s In the Water
11:06
11:12
11:28
11:39
11:45
12:02

Traci PurdumHOST
What are the solutions, um, for dealing with condensate return impurity ingress?

Brad BueckerGUEST
One of the first solutions, and it-- and I say solution, this, this applies to so many different water treatment applications, is obtaining comprehensive analyses on what's in the water.

Brad BueckerGUEST
You can't just say, "Oh, yeah, we can slap this piece of equipment on here and, um, and it's gonna work just fine." You really have to analyze and find out what's in the water.

Brad BueckerGUEST
Like i- in the case history I just mentioned, uh, the plant manufactured five phenol derivatives.

Brad BueckerGUEST
The lab, quote unquote, was just this rudimentary little shed, and the, the plant personnel that analyzed the condensate and other water samples were, were just plant operators.

Brad BueckerGUEST
The test only would indicate one of the five products that could have been in the condensate return, and it would turn-- it was supposed to turn Orange.
8 MINS LATER