And newer systems can have this.
7:58
The discovery in 1986 was the first indication of FAC.
8:02
But going back in time, way back to, you know, fairly early in the last century, you know, boilers started to increase in pressure and size as they became used for power generation.
8:16
You know, as electricity expanded around the country, you know, everybody wanted to have power.
8:22
Well, we've got to generate the power and fossil fire boilers, coal fire boilers and others, oil fire boilers, came online to you know, generate the steam that drove the turbines to produce the power.
8:37
So everybody was looking for advancements and higher pressures and temperatures because thermodynamically that improves the efficiency of the entire process.
8:49
Well, during that time, especially in the mid-50s, and again, I'm focusing on the feedwater network of these units, chemists and researchers and so forth had concluded that And I'll back up a little bit.

10 MINS LATER

19:03
And if we figure out that FAC is the problem, how do we correct the situation?
2:48
So my question to you is, what are the earliest, easiest-to-miss signs that one of these out-of-the-way systems is deteriorating, and why do operators so often overlook them?
3:02
Well, i-in the first, uh, place, uh, you know, with these systems being, uh, scattered around, especially at large fa-- utilities and, uh, industrial plants, uh, it, it can be easy to overlook some of the systems, especially maybe some of the small systems.
3:17
So, you know, having good records and, and a, a procedure to inspect systems.
3:23
As far as early detection, um, and, and some of this comes from my own experience, and I'll mention a little bit of, bit of it here in a few minutes.
3:33
But, uh, in cooling systems, scale formation and microbiological fouling can, can cause, obviously, heat transfer degradation.
3:44
And with a good monitoring program, you know, somebody that's experienced and, and has the proper training, uh, they can detect some of these problems coming on, uh, before things really get serious.
3:58
Now with, with microbes, and, and I've dealt with those a lot, that's probably -- And it's not just my opinion, a lot of my colleagues, too, that can be the number one problem.
6:57
Now, why are s- are the potential problems often exacerbated in systems with cooling towers as compared to once-through systems?
5:58
Now, what about the existing equipment and what needs to be done, and what does a well-designed RO pretreatment setup need to include here? to keep the membranes protected over the long term? And where do you see plants cutting some corners on things like this?
6:16
Cutting my teeth in the industry for so many years and learning so many things.
6:21
There are two philosophies that they're kind of counter to each other that I've seen over the years.
6:27
And you kind of have to make evaluations one way or the other.
6:31
One of them is the old saying, if it ain't broke, don't fix it.
6:35
But the other saying is, well, that's what we've always done.
6:39
So, and that can lead to problems too.

9 MINS LATER

15:30
How can operators tell when an RO system is starting to drift out of spec before it becomes a real problem? And what should they be keeping an eye on day to day?
11:06
What are the solutions, um, for dealing with condensate return impurity ingress?
11:12
One of the first solutions, and it-- and I say solution, this, this applies to so many different water treatment applications, is obtaining comprehensive analyses on what's in the water.
11:28
You can't just say, "Oh, yeah, we can slap this piece of equipment on here and, um, and it's gonna work just fine." You really have to analyze and find out what's in the water.
11:39
Like i- in the case history I just mentioned, uh, the plant manufactured five phenol derivatives.
11:45
The lab, quote unquote, was just this rudimentary little shed, and the, the plant personnel that analyzed the condensate and other water samples were, were just plant operators.
11:59
And they had a test.
12:02
The test only would indicate one of the five products that could have been in the condensate return, and it would turn-- it was supposed to turn Orange.

8 MINS LATER

20:42
Oh, good