Search complete. 7 mentions across 6 episodes found for "Uptime Institute, LLC".
Oct 5, 2026
A Journey Through Data Centers | A SleepWise Story
G
58:52Grandpa CohenHOST
This is why some facilities provide alternative routes for power and cooling, allowing equipment to be maintained while the computers continue operating.
G
59:04Grandpa CohenHOST
Uptime Institute describes this capability as being concurrently maintainable.
G
59:11Grandpa CohenHOST
Not every data center is built to the same level, and additional equipment alone does not guarantee uninterrupted service.
G
59:22Grandpa CohenHOST
Procedures matter too, which switch is opened, how a repair is checked, and what the next person needs to know.
The New Power Architecture for AI Data Centers
A
17:13Andy JimenezGUEST
Uh, the, really the, the main point I was gonna add is that a lot of these, uh, redundancy, uh, requirements have been, you know, part of the industry, um, for a long time from a data center perspective.
A
17:23Andy JimenezGUEST
So, uh, there's been organizations like the Uptime Institute as well as the, uh, Telecommunications Industry Association.
A
17:31Andy JimenezGUEST
Uh, they established a tiering program, so there's, there's four tiers, tier one being just a basic, what we call basic infrastructure.
A
17:38Andy JimenezGUEST
So to the critical path that, you know, David, you know, talked about, if you have your electrical primary path to the critical load, a basic infrastructure means no redundant components built in.
No One Sends Your Business a Reminder; So Here It Is
M
18:02Maartje van KriekenHOST
This is about between, it's about Q4, really, or between now and year end, or even just the next 90 days, because by December, it's done, right? So what's really actually genuinely coming in and what's genuinely going out and where are the gaps and where are the assumptions and where are the reserves? Where have been the major hiccups and where did you say that you were going to make it up? And can you still? Q4 always has surprises, right? And the question is whether you know where your actual buffer is right now versus where you thought it maybe was in January.
M
18:45Maartje van KriekenHOST
And the reason why this matters is that more than half of the respondents to the 2024 Uptime Institute survey said that their most recent significant outage costed them more than $100,000.
M
18:59Maartje van KriekenHOST
And one in five said it cost them more than a million.
M
19:04Maartje van KriekenHOST
And 90% of mid-sized and large enterprises lose upwards of $300,000 per hour of downtime And for 41% of the enterprises, that figure reaches 1 to 5 million per hour.
Protecting the Cloud: Data Centre Fire Protection with JCI
C
22:12Chris DowneyGUEST
And I think that's something I'd love to see happen.
C
22:15Chris DowneyGUEST
The Uptime Institute has it.
C
22:16Chris DowneyGUEST
And what was interesting, the outage data this year, not only did they declare what a fire is, this year I think they said 6% of outages.
C
22:25Chris DowneyGUEST
Don't hold me to that number.
What If Your Prompt Could Feed Someone a Strawberry?
A
2:19Artificial IntelligenceNARRATOR
The industry-wide average sits at 1.
A
2:22Artificial IntelligenceNARRATOR
52 in Uptime Institute's 2026 survey, recent builds routinely post 1.3 orbiter, and the biggest hyperscale fleets report numbers close to 1.1.
A
2:33Artificial IntelligenceNARRATOR
But PUE measures how efficiently you reject heat.
A
2:37Artificial IntelligenceNARRATOR
It has no term for whether the heat did anything useful after it left the rack.
Climate News: Naomi Klein on the war to survive and supremacist governments; AI centre threat in Melbourne; Heat deaths will continue, unconscionable behaviour in U.S.
S
5:25speaker_2CORRESPONDENT
In a media release, CEO Craig Scroggie said M4 would have direct-to-chip closed-loop cooling supporting rack densities of 1,000 kilowatts using recycled non-potable water.
S
5:37speaker_2CORRESPONDENT
M4 has all the top-tier global safety certificates, including the prestigious Tier 111 and Tier 4 certifications from the Uptime Institute, which sets the global standard for evaluating data centre reliability, availability and performance.
S
5:53speaker_2CORRESPONDENT
NextDC did not return calls for comments on the fire risk.
S
5:56speaker_2CORRESPONDENT
Ironically, the elaborate cooling systems used to cool the computers in data centres can cause fires.
S
6:03speaker_2CORRESPONDENT
As the climate warms and facilities attempt to minimise cooling for efficiency reasons, we could see a trend for cooling system failures, wrote Peter Judge in Data Centre Dynamics magazine.
S
6:14speaker_2CORRESPONDENT
Judge is now a senior research analyst with the Uptime Institute.
S
6:18speaker_2CORRESPONDENT
He told Michael West Media he still stood by these quotes, reporting that a cooling system caused a fire in China in October 2022.
S
6:27speaker_2CORRESPONDENT
A backup cooling tower caught fire in the block that houses the data center at China's Suzhou Supercomputing Center in the Suzhou Industrial Park, a technology and business flagship for the country.